7 research outputs found

    A perspective of the comprehensive and objective assessment of analytical methods including the greenness and functionality criteria : application to the determination of zinc in aqueous samples

    Get PDF
    The recently proposed concept of White Analytical Chemistry (WAC), referring to the Red-Green-Blue color model, combines ecological aspects (green) with functionality (red and blue criteria), presenting the complete method as “white”. However, it is not easy to carry out an overall quantitative evaluation of the analytical method in line with the WAC idea in an objective manner. This paper outlines the perspective of the future development of such a possibility by attempting to answer selected questions about the evaluation process. Based on the study consisting in the evaluation of selected model methods by a group of 12 independent analysts, it was shown how well individual criteria are assessed, whether the variability of assessments by different people is comparable for each criterion, how large it is, and whether averaging the scores from different researchers can help to choose the best method more objectively

    The effect of the selected cellular reductants on the release of manganese from the manganese-lactoferrin complex

    No full text
    Laktoferyna jest glikoproteiną należącą do rodziny transferyn. Białko to naturalnie występuje w ludzkim organizmie, a jego stężenie zależy od miejsca występowania – największe jest w siarze i mleku. Laktoferyna nazywana jest białkiem multipotencjalnym ze względu na cały wachlarz pozytywnych funkcji, jakie pełni w organizmie – od wychwytywania wolnego żelaza do modulacji układu odpornościowego. Białko to posiada dwa miejsca wiążące, w których najchętniej wiąże jony żelaza(III). W niniejszej pracy wzięto pod lupę manganową pochodną laktoferyny. Charakteryzuje ona się stopniowym, kontrolowanym uwalnianiem jonów manganu(III), co wydaje się być interesujące w kontekście wykorzystania jej jako potencjalnego składnika suplementów prebiotycznych. W pracy tej skupiono się na zbadaniu wpływu wybranych reduktorów komórkowych na uwalnianie jonów manganu z kompleksu manganowej pochodnej laktoferyny. Przebadano trzy reduktory – kwas askorbinowy, glutation i cysteinę. Otrzymane wyniki wykazały, iż najsilniejszy z antyoksydantów tj. glutation, nie jest w stanie zredukować jonów manganu w laktoferynie, tym samym przyspieszyć uwalnianie ich z białka. Pozostałe reduktory jedynie w niewielkim stopniu przyspieszają uwalnianie jonów manganu z badanego białka. Odporność badanego kompleksu na redukcję zwiększa jego szansę na zostanie potencjalnym suplementem diety.Lactoferrin is a glycoprotein belonging to the transferrin family. This protein naturally occurs in the human body, and its concentration depends on the place of occurrence - the highest is in colostrum and milk. Lactoferrin is called a multipotent protein because of the whole range of positive functions it performs in the body - from free iron capture to modulation of the immune system. This protein has two binding sites where it most often binds iron(III) ions. In this work, a manganese derivative of lactoferrin was investigated. It is characterized by a gradual controlled release of manganese(III) ions, which seems to be interesting in the context of using it as a potential ingredient in prebiotic supplements. This work is focused on investigating the effect of the selected cellular reductants on the release of manganese ions from the manganese-lactoferrin complex. Three reductants were tested - ascorbic acid, glutathione and cysteine. The obtained results showed that the strongest of antioxidants, i.e. glutathione, is not able to reduce manganese ions bound to lactoferrin, thereby accelerating their release from protein. Other reductants only slightly accelerate the release of manganese ions from the tested protein. The resistance of the studied complex to reduction increases its chance to become a potential food supplement

    Determination of acidic dissociation constant of selected biologically active compounds using continuous flow analysis technique

    No full text
    Praca dotyczy wyznaczania wartości pKa wybranych substancji biologicznie aktywnych (warfaryny i hydroksypochodnych kumaryny) w przepływie ciągłym z detekcją spektrofotometryczną. Wartość pKa jest jednym z najważniejszych fizykochemicznych parametrów opisującym właściwości związków chemicznych. Głównym celem pracy było opracowanie oraz walidacja szybkiej metody wyznaczania pKa w przepływie ciągłym. Praca podzielona jest na dwie części. W część teoretycznej pracy scharakteryzowano metody analizy przepływowej, opisano stałą dysocjacji kwasu, zestawiono przykłady metod umożliwiających wyznaczenie pKa, a także krótko scharakteryzowano substancje poddane badaniom. W części doświadczalnej pracy opisano metodykę realizowanych badań, przeprowadzone badania wstępne wraz z etapami doboru optymalnych parametrów układu oraz sposób wyznaczenia stałej dysocjacji. Zasada metody polega na wyznaczeniu wartości pKa na podstawie dwóch zdefiniowanych zależności. Weryfikację metody przeprowadzono z wykorzystaniem wskaźników kwasowo-zasadowych, aby następnie zastosować ją do wyznaczenia wartości pKa pochodnych kumaryny. Otrzymane wyniki charakteryzują się dobrą precyzją i w większości są zgodne z wartościami literaturowymi. W obliczeniach wprowadzono poprawkę uwzględniającą siłę jonową. Opracowana metoda wyznaczania stałej dysocjacji pozwala na mechanizację procesu, wyznaczenie parametru w krótkim czasie przy niewielkim zużyciu odczynników.The presented thesis concerns the determination of acidic dissociation constants of selected biologically active compounds (warfarin and hydroxycoumarins) using continuous flow analysis with spectrophotometric detection. Acidic dissociation constant is one of the most important physicochemical parameter characterizing properties of chemical compounds. The main aim of the work was to develop and validate fast method of pKa determination in continuous flow. The thesis is divided into two parts. In the literature section, the flow analysis methods were characterized, the acid dissociation constant was described, examples of methods enabling pKa determination were summarized, and the substances under study were briefly characterized. The experimental part of the thesis describes the methodology of the conducted research, the preliminary tests carried out along with the stages of selection of optimal system parameters and the method of determining the dissociation constant. The principle of the method was to determine the pKa value based on two defined relationships. The method was verified using acid-base indicators and used to determine the pKa value of coumarin derivatives. The results obtained were characterized by good precision and were mostly consistent with literature values. Ionic strength correction was introduced in the calculations. The developed method of determining the dissociation constant allows mechanization of the process, determination of the parameter in a short time with low consumption of reagents

    Ethical and legal aspects of prenatal diagnosis

    No full text
    Celem pracy jest przedstawienie rodzajów badań prenatalnych oraz opis etycznych i prawnych aspektów z nimi związanych. Przedstawiono w niej dane z prac przeglądowych z zakresu lat 2000-2014 oraz dostępnej literatury. Sytuację prawną w Polsce opisano na podstawie ustawy o planowaniu rodziny, ochronie płodu ludzkiego i warunkach dopuszczalności przerywania ciąży z dnia 7.01.1993r.W pracy przedstawiono rodzaje badań prenatalnych i scharakteryzowano ich funkcje, oraz ryzyko powikłań występujących podczas ich wykonywaniaPorównano również stanowiska podstawowych teorii etycznych (personalizmu i utylitaryzmu) oraz kierunków politycznych (liberalizmu i konserwatyzmu) dotyczących badań prenatalnych. Personaliści skupiają się przede wszystkim na zasadzie potencjalności twierdząc, że każdy organizm ludzki od momentu poczęcia jest osobą w znaczeniu normatywnym, czyli posiada status moralny. Przyznają oni również człowiekowi bezwzględne prawo do ochrony zdrowia i życia od momentu poczęcia.Zwolennicy utylitaryzmu swoje przekonania opierają na zasadzie użyteczności, czyli maksymalizacji korzyści i minimalizacji strat. Jeśli więc urodzenie się człowieka niepełnosprawnego miałoby doprowadzić do krzywdy np. rodziców poprzez przysporzenie im ciężaru obowiązków i rezygnacji z własnych aspiracji życiowych, dochodzą do wniosku, że lepszym rozwiązaniem jest przerwanie ciąży.Liberałowie dają pełną swobodę rodzicom jeśli chodzi o podejmowanie wszelkich decyzji w zakresie prokreacji. Dotyczy to zarówno wykonywania badań prenatalnych jak i stanowienia o genotypie potomstwa.Przedstawiciele orientacji konserwatywnej cechują się otwartością na wszystko, co jest darem od losu, natury, czy Boga. Wierzą, że nie mają wpływu na przymioty jakie otrzyma ich potencjalne potomstwo.The purpoe of disseration is to prezent the types of prenatal tests and a description of the associated with them ethical and legal aspects.There are shown data from the reviews, made between year 2000 and 2014 and the available literature.The legal situation in Poland is described on the basis the Act on family planning, protection of the human fetus and conditions of permissible abortion of 7.01.1993r.The study presents types of prenatal tests and characterized their functions, and the risk of complications during their executionThere was also compared positions of basic ethical theories (personalism and utilitarianism) and political orientation (liberalism and conservatism) that address prenatal tests.Personalists focus primarily on the principle of the potentiality, arguing that every human organism from the moment of conception is a person in the sense of a normative, that it has moral status. They also confer an absolute right to human health and life from the moment of conception.Proponents of utilitarianism their beliefs are based on the principle of utility, that is, to maximize the benefits and minimize losses. So if the birth of a man with a disability would lead to harm for example Parents by increasing the amount of the burden of responsibility and resignation from their life aspirations, come to the conclusion that a better solution is to terminate the pregnancyLiberals give full freedom to the parents when it comes to making any decisions regarding procreation. This applies to both prenatal testing and regulation of the genotype of the offspring.Representatives of conservative orientation characterized by the belief that everything is a gift from fate, nature, or God. They believe that they have no influence on the attributes that will get their potential offspring

    Novel integrated flow-based steam distillation and titration system for determination of volatile acidity in wines

    Get PDF
    Novel integrated flow-based steam distillation and titration system with spectrophotometric detection was developed for determination of volatile acidity in wines. Using the system, the distillation procedure was carried out in an automatic manner, starting with introducing into a heated steam distillation module a sample and subjecting it to steam distillation. Under selected conditions, all the analyte was transferred to the distillate; therefore, the system did not require calibration. The collected distillate and titrant were introduced into the next monosegments in varying proportions, in accordance with the developed titration procedure, and directed to the detection system to record the titration curve. The titration was stopped after reaching the end point of titration. Procedures for distillation and titration were developed and verified separately by distillation of acetic acid, acetic acid in the presence of tartaric acid as well as acetic acid, tartaric acid, and titratable acidity, with precision (relative standard deviation) and accuracy (relative error) for both procedures lower than 6.9 and 5.6%, respectively. The developed steam distillation and titration systems were used to determine volatile acidity in samples of white and rosé wines separately and as the integrated steam distillation and titration system, both with precision lower than 9.4% and accuracy better than 6.7%
    corecore